BYHKW - ELEKTROGUARD SILICONE ELASTOMER 2100

  • MSDS: BYHKW
  • Manufacturer: WACKER SILICONES CORP
  • Product Name: ELEKTROGUARD SILICONE ELASTOMER 2100
  • National Stock Number: 5970-01-314-8477
Product Identification

Product ID:ELEKTROGUARD SILICONE ELASTOMER 2100
MSDS Date:10/22/1993
FSC:5970
NIIN:01-314-8477
MSDS Number: BYHKW

Responsible Party
WACKER SILICONES CORP
3301 SUTTON RD
ADRIAN, MI 49221
US

Emergency Phone: 517-264-8500/800-424-9300(CHEMTREC)

Info Phone: 517-264-8500

Cage: 0DF77

Contractor
WACKER SILICONES CORP
ADRIAN, MI 49221 US

Telephone: 517-264-8500

Cage: 0DF77

Ingredients

NO INGREDIENT FOR THIS FORMULATION_INGREDIENT

Hazards

LD50 LC50 Mixture:HAS NOT BEEN ESTABLISHED
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE/SKIN/INHAL:NO TOXIC EFFECTS
EXPECTED.INGEST:NOT EXPECTED IN INDUSTRIAL USE.ACUTE EFFECTS:NONE
KNOWN.CHRONIC EFFECTS:MAY CAUSE LUNGE DMG @HIGH CONCEN OR ON
REPEATED EXPO.MATL RELEASES ETHYL ALCOHOL UPON HYDROLYSIS WHICH
IRRIT EYES/MUC MEMB.OVEREXPO HAS SHOWN TO CAUSE CNS DEPRESSION.EYES
WILL BURN & STING.(SUPPLEM)
Explanation of Carcinogenicity:PER MSDS:MATL DOES NOT CONTAIN ANY
INGREDS LISTED BY IARC/NTP/OSHA AS CARCINOGENS IN AMTS EXCEEDING
0.1%.
Effects of Overexposure:CHRONIC EFFECTS OF EXPO:MAY CAUSE LUNG DAMAGE
AT HIGH CONCENTRATIONS OR ON REPEATED EXPOSURE.
Medical Cond Aggravated by Exposure:THERE ARE NO DATA AVAILABLE WHICH
ADDRESS MED CONDITIONS WHICH ARE GENERALLY RECOGNIZED AS BEING
AGGRAVATED BY EXPOSURE TO THIS PRODUCT.

First Aid

First Aid:EYE:FLUSH WELL W/WATER FOR 15MINS.IRRIT OCCURS OBTAIN MED
ATTN. SKIN:REMOVE EXCESS MATL W/WATERLESS SKIN CLEANER.FLUSH
W/PLENTY OF WATER.WASH WELL W/SOAP/WATER.REMOVE CONTAMIN
CLOTH/SHOES.IRRIT OCCURS OBTAIN MED ATTN. INHAL:REMOVE TO
FRESHAIR.RESP IRRIT OCCURS/BREATH DIFFICULT SEEK MED ATTN.
INGEST:NOT APPLICABLE.

Fire Fighting

Flash Point Method:PMCC
Flash Point:166F,74C
Lower Limits:N/DETERMINED
Upper Limits:N/DETERMINED
Extinguishing Media:USE CARBON DIOXIDE, DRY CHEMICAL, OR FOAM TYPE
EXTINGUISHING MEDIA.
Fire Fighting Procedures:PREVENT HUMAN EXPO TO FIRE/SMOKE/FUMES/COMBUST
PRODS.EVACUATE NON-ESSENTIAL PEOPLE FRM FIRE AREA.FIREFIGHTERS
SHOULD WEAR FUL-FACE,SCBA,IMPERVIOUS PROT CLOTHING
Unusual Fire/Explosion Hazard:PRODUCT CONSIDERED COMBUSTIBLE;FIRE
HAZ.SUPPORTS COMBUSTION/DECOMPOSES UNDER FIRE CONDITIONS TO GIVE
OFF TOXIC MATLS.FKANN VAP MAY ACCUMULATE IN CNTNR (SUPPLEM)

Accidental Release

Spill Release Procedures:REMOVE ALL IGN SOURCES.CONTROL SPILL W/O
RISK.CLEANUP CREW FOLLOW GOOD INDUSTRIAL HYG PRACT.USE
+PRESSURE/SCBA/+PRESS SUPPL AIR RESP W/ESCAPE PACK.ABSORB
W/SAND/FULLER EARTH.SWEEPUP/PLACE IN CHEM WAST E CNTNR.FLUSH
W/WATER.OBSERVE ALL LOC/STA/FED REGS
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:HYDROLYSES SLOWLY @AMB TEMP WHEN EXPO
TO MOIST AIR FORMING ETHYL ALCOHOL.KEEP CNTNR CLSD TO PREVENT EXPO
TO MOISTURE.STORE IN COOL DRY WELL VENTI AREA
Other Precautions:OPN CNTNR W/CARE.NEVER USE WELD/CUT TORCH NEAR EMPY
CNTNR.CONTAIN METHYL POLYSILOXANE WHICH GENERATES FORMALDEHYDE VAP
WHEN EXPO TO >302F IN PRESENCE OF AIR.SAFE USE CONDITONS CAN BE
ENSURED BY MONITO R/CONTROLL VAP CONCEN IAW 29CFR1910.1048

Exposure Controls

Respiratory Protection:PRODUCT USED UNDER CONDITIONS WHICH GENERATE
AIRBORNE CONTAMIN PROCESSING OPERATIONS SHOULD BE CARRIED OUT IN
OPN WELL VENTI AREAS OR ENCLSD AREAS EQUIP W/LOC EXHAU VENTI.IF NOT
AVAILABLE USE APPROP N IOSH APPROV AIR-PURIFY/SUPPLIED-AIR REP.
Ventilation:LIMIT WORKER EXPO W/GEN VENTI,LOC EXHAU
VENTI,ENCLOSURE/CONFINEMENT OF OPERA &/OR PROCESS ISOLATION
W/REMOTE CNTRL OPERA
Protective Gloves:GLOVES.
Eye Protection:CHEM SAF GLASSES,GOGG,FACESHIELD.
Other Protective Equipment:SUITABLE LONG-SLEEVED CLOTH.SPEC SAFE HNDLG
PRAC FOR VARYING CONDITONS SHOULD BE DEVELOPE BY KNOWLEDGEABLE
PERSON.
Work Hygienic Practices:WASH CONTAMIN CLOTH BEF REUSE.WASH HANDS AFT
HNDLG.EAT/DRINK/SMOKE/COSMETIC APPLI PROHIBITED IN PRODUCT
WORKAREA.
Supplemental Safety and Health
FIRE/EXPLO HAZ:HEADSPACE ON FORMATION OF HYDROLYSIS BY-PRODUCTS. HEALTH
HAZ:CONTAINS METHYL POLYSILOXANE WHICH CAN GENERATE FORMALDEHYDE
VAP WHEN EXPO TO TEMPS >302F INN PRESENCE OF AIR.FORMALDEHYDE P OT
CANC HAZ,CAUSES SKIN/RESP SYS IRRIT/SENS,EYE/THROAT IRRIT,ACUTELY
TOXIC.

Chemical Properties

HCC:V4
Boiling Pt:B.P. Text:NON-VOLATIL
Vapor Pres:NIL
Vapor Density:N/APPLICAB
Spec Gravity:1.49
Solubility in Water:NEGLIGIBLE
Appearance and Odor:RED VISCOUS LIQUID, MILD ODOR.
Percent Volatiles by Volume:NEGLIG

Stability

Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:DO NOT POUR, SPILL, OR STORE NEAR HEAT,
SPARK SOURCES, OR OPEN FLAMES.
Hazardous Decomposition Products:SIO2, CO, CO2, FORMALDEHYDE & VARIOUS
HYDROCARBON FRAGMENTS.

Disposal

Waste Disposal Methods:TOXICOLOGICAL TESTING HAS NOT BEEN CONDUCTED
W/MATL BY WACKER SILICONES CORP.OBSERVE ALL LOC/STATE/FED REGS WHEN
DISPOSING MATL.PREVENT MATL FROM ENTERING PUBLIC/MUNICIPAL
WATERWAYS.UNUSED MATL:APPROV ED FACILITY IAW ANY APPLICABLE REGS
UNDER RCRA.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.